Electrical Reliability for Data Centers

Gain continuous visibility into your electrical infrastructure with engineered electrical safety technologies designed for modern data centers.

  • Reduce electrical safety risks
  • Maximize uptime and system availability
  • Protect critical power infrastructure

Power Reliability is Non-Negotiable

Modern data centers depend on uninterrupted power to support critical digital infrastructure. Even minor electrical issues can result in service interruptions, equipment damage, lost revenue, and reputational risk. As facilities grow in complexity and density, operators require greater visibility into electrical system health while maintaining the highest standards of safety and reliability. I-Gard technologies help data center operators detect problems early, improve fault management, verify electrical safety, and support continuous operation of mission-critical systems.

Electrical Challenges in Data Centers

Constant Uptime

Electrical faults and unplanned outages can disrupt critical operations and impact service availability.

Personnel Safety

Maintenance teams require safe methods for verifying de-energized conditions while minimizing exposure to energized equipment.

Hidden Ground Faults

Undetected ground faults can compromise system reliability and increase the likelihood of equipment damage.

Power System Reliability

Operators need real-time insight into system health to identify developing issues before they become failures.

Supporting Compliance & Best Practices

Data center electrical systems are commonly designed and maintained in accordance with:

  • Canadian installations follow CSA C22.1, the Canadian Electrical Code, including its requirements for ground fault protection and for continuous monitoring of the grounding resistor on resistance-grounded systems (Table 17).
  • CSA Z462 governs workplace electrical safety practices, including verification of an electrically safe work condition.

  • I-Gard equipment applied in data centers is UL listed for its intended function: relays and grounding assemblies under their respective listings, and absence of voltage testers under UL 1436.
  • Listing documentation is available on each product page.

  • International deployments commonly reference the IEC 60364 series for low-voltage installations and IEC 61557 for equipment used to test and monitor protective measures.
  • Confirm the specific parts that apply to your jurisdiction and facility classification during design.

Always consult applicable standards and project requirements when designing electrical systems.

Reliability Starts with Visibility

In mission-critical environments electrical issues must be identified before they impact operations. By combining grounding technologies with advanced monitoring solutions, operators gain the information needed to make proactive decisions and can avoid reacting to failures.

Proper grounding and continuous monitoring helps operators:

  • Detect faults early
  • Improve system reliability
  • Reduce equipment damage
  • Simplify troubleshooting
  • Support maintenance planning
  • Enhance personnel safety

Avoid Downtime with the Right Solutions

DSP-OHMNI

Continuously monitors resistance-grounded electrical systems and provides advanced ground fault detection, alarming, and fault location capabilities. When a ground fault occurs, the system identifies the affected feeder and phase while providing pulsing functionality to help maintenance personnel quickly locate the faulted circuit without disrupting operations.

Installed on high-resistance grounded distribution systems serving critical power infrastructure such as switchgear, UPS systems, power distribution equipment, and electrical rooms where rapid fault identification and continuous operation are essential.

Primary Benefit: Reduce fault investigation time and maintain operational continuity.

Neutral Grounding Resistor

Limits ground-fault current to a low, designed value by placing a resistor between the system neutral and ground, so a first phase-to-ground fault does not develop the current needed to damage equipment or sustain an arc.

Switchgear and circuits where a facility needs to reduce incident energy on top of whatever ground fault protection is already in place.

Primary Benefit: Reduces the incident energy of an arc flash that is already in progress. This is the mitigate half of the prevent-and-mitigate pair, with high-resistance grounding covering the prevent half.

Learn More
Absence of Voltage Testers

A permanently installed tester that verifies an absence of voltage from outside the enclosure. A supervisory circuit confirms the device’s own function before and after every test, and results are returned in under 10 seconds.

Fitted to distribution equipment, switchgear, and electrical rooms where maintenance teams must confirm a de-energized state before work begins.

Primary Benefit: Verify a de-energized state without opening the panel.

Learn More
Load Banks

Applies a controlled, measurable electrical load so standby generators and UPS systems can be commissioned and routinely proven under realistic conditions rather than assumed to be ready.

Used at commissioning and on a maintenance schedule for the backup power systems that a data center depends on during a utility event.

Primary Benefit: Prove backup power performs before you need it.

Learn More
ZORC

Protects equipment from steep-fronted transient overvoltages and switching surges by damping the transient before it stresses winding insulation.

Installed at motors, transformers, and switchgear within the facility’s distribution and cooling infrastructure.

Primary Benefit: Reduce insulation stress and extend equipment life.

Learn More
Impedance Monitoring

Continuously verifies the integrity of the grounding path itself, alarming if the resistor or its connection drifts outside its set value, opens, or shorts.

Applied wherever a resistance-grounded system must remain provably protected between maintenance intervals, satisfying continuous monitoring requirements.

Primary Benefit: Know the grounding path is intact, continuously.

Learn More

High Resistance Grounding for Data Centers

A constant issue facing data centers is electrical reliability. Significant focus, attention and capital are applied to backup power systems, which include generators, batteries and UPS. These systems protect critical processes and power factor correction equipment but an often-overlooked issue remains electrical ground faults. It has become standard for data centers to utilize high-resistance grounding as the method of choice. Originally, high-resistance grounding as a technology was applied to process industries as diverse as food processing, mining and petrochemical. In the last 10 years it has been increasingly applied to commercial installations such as airports, data centers and hospitals to enhance the reliability and uptime of power distribution equipment.

How HRG Systems Work Today

The original HRG system developed in the 1950’s and 1960’s provided process continuity, however, they were unable to solve potential safety issues, such as a second ground fault, leaving the ground on the system too long and monitoring of the neutral path.

However, the modern relay can be programmed to prevent this and only shunt-trip the lesser priority feeder, leaving the more important feeder on-line.

Why Data Centers Choose I-Gard

For more than 40 years, I-Gard has helped organizations improve electrical safety, system reliability, and operational performance through engineering-driven solutions for critical power applications. By manufacturing both the current-limiting resistor and ground fault relay in-house, we deliver fully integrated solutions that are tested as a complete system to ensure quality, reliability, and performance.

Our engineering team works closely with consultants and end users to develop solutions tailored to specific system requirements, operating environments, and project objectives. With the industry’s broadest range of high-resistance grounding solutions, from economical designs to advanced monitoring technologies, I-Gard helps data center operators improve fault detection, enhance reliability, and support safer electrical systems.

From specification support and system design through training and commissioning, we stand behind every solution we provide, giving customers confidence in the safety and performance of their critical electrical infrastructure.

Application questions?

Build a More Reliable Electrical Infrastructure

Whether you’re designing a new facility, expanding capacity, or improving operational resilience, I-Gard can help identify the right electrical safety and reliability solutions for your application.